An injection pressure value is only useful when its meaning is clear. Before comparing a cap-mould simulation with a machine specification or a trial report, identify the pressure type, location, units and point in the cycle. Two numbers headed “injection pressure” may describe different things.

This guide covers interpretation and a simple hydraulic-to-plastic pressure calculation. It does not calculate the pressure required to fill a particular cap, prescribe machine settings or replace a mould-and-machine compatibility assessment.
Identify what the number represents
Hydraulic pressure relates to the hydraulic injection drive. Specific plastic pressure relates to the pressure applied to the melt at the injection unit. Cavity pressure concerns the material inside the mould cavity. They should not be entered into one comparison table as though they were the same measurement.
RJG’s explanation of hydraulic, specific and cavity pressure distinguishes these quantities and the effects of intensification and pressure loss. Its practical relevance for procurement is simple: ask the supplier to label the value before deciding whether the available machine is suitable.
Use the original machine documentation for the installed injection unit and screw. A screen photograph can help, but include the field name and displayed unit. Do not infer the pressure basis from the machine brand or its clamp-tonnage designation.
Use the correct intensification ratio
For an applicable hydraulic injection unit, an idealised relationship is:
Plastic pressure = hydraulic pressure × intensification ratio
The ratio relates the effective hydraulic piston area to the screw area. Autodesk’s machine intensification guidance explains this calculation, directs the reader to the machine manual and notes that the relationship neglects losses.
Use the ratio for the actual screw and injection-unit configuration. Do not assume every machine is 10:1. Also establish whether the controller already displays a converted plastic-pressure value; multiplying that figure again would not be the intended conversion. The hydraulic conversion is not a general rule to apply to every electric or hybrid machine display.
A worked example for interpreting a report
Assume a hypothetical report contains a hydraulic pressure of 6 MPa, and the applicable documented intensification ratio is 12:1. The idealised plastic-pressure equivalent is:
6 MPa × 12 = 72 MPa = 720 bar
The unit conversion is 1 MPa = 10 bar. The ratio has no unit. These invented teaching inputs describe no Mincong trial, resin recommendation or approved operating condition.
The calculation does not mean that every cavity experiences 72 MPa. It also does not establish that the machine can deliver a required injection rate at that pressure. It provides one clearly labelled equivalent for interpreting the report; performance and measurement questions remain open.
When receiving a calculation, keep the original number, unit, ratio source and converted result together. That allows the machine team to check the basis without reconstructing it from a final figure alone.
Keep simulation and measured results identifiable
A simulation result has a defined output location and time. Autodesk’s pressure-at-switchover documentation describes a pressure distribution at the velocity-to-pressure transition. It is not an undifferentiated pressure value for the entire cycle.
Ask which result is being quoted: pressure at the injection location, a cavity distribution at a specified stage, or another output. Keep the modelled resin, geometry, feed-system scope and analysis conditions attached to the report. A result from a model that omits relevant flow-path components needs that limitation stated.
Likewise, label trial data by its actual source. If a number is described as measured cavity pressure, ask where and how it was measured. A converted machine value must remain identified as such, rather than becoming an undocumented cavity-sensor result.
Compare a complete evidence row
The following is a proposed review format, not a machine-setting sheet:
| Value supplied | Information to keep with it |
|---|---|
| Machine pressure capacity | Installed injection unit, screw and manufacturer’s definition |
| Hydraulic value | Source field, units and applicable conversion basis |
| Converted plastic value | Original hydraulic value, documented ratio and calculation assumptions |
| Simulation result | Output type, location, cycle stage and model scope |
| Measured cavity value | Sensor location, measurement basis and identified trial samples |
Also distinguish a capacity rating, a programmed limit and an observed result. Ask the responsible machine or process specialist to confirm the definitions used by the particular controller. A maximum catalogue number alone does not describe the complete trial condition.
For installation and equipment inputs beyond pressure, use our cap mould and injection-machine compatibility guide. It covers a different decision from this calculation.
Do not substitute injection pressure for a clamp calculation
Clamping is a separate assessment. A pressure quoted at the injection unit is not automatically the cavity-pressure basis needed for estimating mould-opening force. Copying it directly into a projected-area calculation can create a misleading result.
Our clamping-force review explains that estimate and its assumptions. Keep its cavity-pressure basis explicit rather than using whichever pressure number is easiest to find.
Before approving a water or beverage cap mould, request the actual machine specification, labelled pressure data and the relevant simulation or trial report if available. Send those documents for a mould review, with missing definitions marked openly. A transparent comparison is more useful than a single pressure figure presented as proof of compatibility.