Clear PET Preform, White Gate: What Should You Check First?

Clear PET Preform, White Gate: What Should You Check First?
White halo at the gate of a clear PET preform
Illustration of local whitening at a preform gate.

Pull a preform from a steady run and look at the base. If the body is clear but a white patch surrounds the gate, record the defect before changing the drying or temperature settings. Is the mark inside the material, or is it a raised or torn feature on the surface? Those observations point to different checks. A white area can be consistent with gate crystallinity, but colour alone does not confirm it.

First, map the defect by cavity and time

What you seeNext check
The same cavity has an internal white patch at the gate on consecutive shotsCompare that cavity’s gate-area cooling and nozzle conditions with a good cavity. Have maintenance check for local cooling restrictions if the pattern persists.
Several cavities turn white at the base after a cycle or cooling-water changeCompare current cooling supply, cycle timing and take-out cooling with the last accepted run.
The mark is raised, torn or projects from the surfacePhotograph the side profile and compare gate projection and finish with the approved sample. Review the gate or valve-pin condition before treating it as internal whitening.
The area looks clear straight out of injection and turns white only after blowingKeep matched preform and bottle samples. Investigate the blowing stage before attributing the mark to the injection gate.

Use consistent lighting and mark the cavity numbers before samples are mixed. Record how long after startup the patch appears. If you run a controlled process comparison, change one factor at a time within the approved window and repeat the same inspection on both good and affected cavities.

What to send your toolmaker: One affected sample and one accepted sample, close-up photos from the side and base, cavity numbers, and the last recorded change to cooling, cycle or nozzle settings.